Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Checklist fire door inspection report template.
This may result in a requirement for the doors to be.
Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
Fire door inspectors can complete fire door inspections in the field by using this revolutionary mobile fire door inspection software.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.
Chris i have no problem in checklists but in this area if you need a checklist wrt fire door inspection then maybe it should be left to some one that does not.
Check the door frame bolts hinges locks fire exit hardware door closers and other significant parts for defects in need of repair or replacement.
The door operates smoothly and quietly without binding or scraping grinding noises.
Checks visual and operating checks only door door door door door door warning keep hands away from the door door operator safety devices operation.
View the vision panel and glass from both sides of the door.
To ensure the safety of a building s occupants regular checks must be performed on all fire doors.
This detailed fire door inspection checklist can be used to survey the overall condition of fire doors.
Open the door and take a look at the hinges.
Still a checkmate fire gap gauge take a look at the edges of the door and frame.
This fire alarm inspection report template can help fire safety officers to easily.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
Door owner s monthly inspection checklist sectional doors location.
Open the door about halfway let go and see.
Fire doors can only be effective though if they are maintained to the highest standards and are fit to perform their intended function in the event of a fire outbreak.
The frequency of each inspection should be determined by assessing among other things the amount of use the door is subjected to the criticality of the area and who it protects.
For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick.
As i ahve said a check list will not cover all types of doors or situations but no doubt some one else will say other wise.
Fire doors basic guidance checklist introduction.